13442 SW 131 STREET
MIAMI, FL 33186
(786) 242-2292
Fax: (786) 242-2297
 

<<<Español
 
 
 
 
 
 
 
 
 
 
 
 
 
loans button
 

hycom

HT2000-SINGLE SYSTEM-X350


Model: HT2000-2-E/1-S-X350
Flow range: 0-55 USGPM
 

Features
•Single system with one pressure and one return line.
•Pressure range: 300-5000 psi, 20-350 bar.
•Power connection: 250 amp - 50 Hz / 200 amp - 60 Hz.
•Current standard: 400/690 V - 50 Hz, other on request.
•Noise level: less than 75 dbA at 1 mtr distance.
•Axial piston pump variable stroke with proportional control of flow and pressure.
•Boost pump for closed loop circuit.
•Open loop configuration for filling and draining of A/C reservoir.
•Pressure filter 3 micron absolute, boost filter 3 micron absolute with electric clogging indicators.
•Fluid contamination level NAS 1638 class 6 or better.
•Sample point.
•Stainless steel reservoir of 240 ltr. with drain valve and filling cap.

•Air/oil cooler with low noise level suitable for tropical conditions. •Analogue pressure gauge 0-6000 psi in pressure and 0-200 psi in return line. Accuracy 1% of f.s. •Digital read out of actual flow suitable for TARAN or ITCAN leak test procedures. Accuracy 0,3% of
measured value.
•Flow setting by potentiometer. Set flow display will indicate the value of selected flow.
•Pressure setting by push button + and -.
•Key switch for operation 3000/5000 psi.
•Temperature and boost pressure shut down switches, emergency shut down button.
•Operator panel with graphic lay-out for easy operation and protection cover.
•Main power supply cable 12 mtr.
•Hydraulic hoses with length of 9 mtr. stowed on electric driven hose reel.

•Heavy duty frame with drip tray. Hydraulic and electric components completely isolated from each other.
•Canopy out of steel, spray painted with Sikkens Aerodur skydrol resistant paint.
•Max. allowable towing speed 16 km/hour, parking brake on front wheels by tow bar in upright position.
•Tie down/lifting points. Fork-lift pick-up points.
•Weight 2700 kg, dimensions 3680 x 1750 x 1625 mm.

Options possible
Z = Parker quick disconnect couplings to connect hoses to the aircraft
U = Hoses with length of 12 mtr.
RC = Remote control
L = Mineral oil based fluids.

HT55-SINGLE SYSTEM-X350
HT2000-SINGLE SYSTEM
HT-DOUBLE SYSTEM-D
HT60-DUAL SYSTEM-S2
HT2000-SINGLE SYSTEM-X350
HT-SINGLE SYSTEM
HT2000-DOUBLE SYSTEM-D
HT2000-SINGLE SYSTEM-ENGINE DRIVEN
 

13442 SW 131 STREET MIAMI, FL 33186 | (786) 242-2292 | Fax: (786) 242-2297